VestasV27_225kW_27¶
Key Parameters¶
Item |
Value |
Units |
---|---|---|
Name |
V27 |
N/A |
Rated Power |
225 |
kW |
Rated Wind Speed |
15.5 |
m/s |
Cut-in Wind Speed |
3 |
m/s |
Cut-out Wind Speed |
25 |
m/s |
Rotor Diameter |
27 |
m |
Hub Height |
31.5 |
m |
Drivetrain |
Geared |
N/A |
Control |
Pitch Regulated |
N/A |
IEC Class |
N/A |
The performance data comes from a power performance test conducted by Risø National Laboratory in Denmark (now DTU Wind Energy) 1.
Power curve¶

Cp curve¶

References¶
- 1
Søren Markkilde Petersen. 1990. Wind Turbine Test Vestas V27-225 kW. Roskilde, DK: Risø National Laboratory. Risø-M-2861. https://www.osti.gov/etdeweb/servlets/purl/7795314.